low energy
comsumption
high efficency

Technical Details

Input / Power feeding

110 – 230V/AC; 50 – 60Hz

High Voltage Output

25 – 60kV/DC; 0,5 – 1,5mA

Control Signal

normally open switch
(NO); potential-free

Disturbance signal

normally open switch (NO);
potential-free

Grounding

16mm² to the equipotential

Energy consumption

0,2 – 0,35 kW

What is the principle of preciption?

High voltage creates free electrons, which ionise the air. The ionisation charges the dust particles and they collect on the collector. This collector is the inside of the housing, where the dust particles are shaken off by a periodically running vibration motor.

Where can a system be installed?

Our systems are suitable for different situations in bulk materials handling. Especially for the conveyor material transfer points, at the chute outlet opening, for the crusher or feeder and screen outlet´s as well as on top of the silos.

What are the advantages?

  • Very low operating costs
  • Very low power consumption
  • Very low maintenance costs (no additional downtime required)
  • No water required
  • No change in material properties
  • No loss of material

Our systems guarantee very high dust suppression with extremely low operating and maintenance costs.